Category Archives: Management Pack Downloads

Logical Disk Free Space Monitor (extended)

The question of how to manage the logical disk free space monitor comes up time and time again. Just about every customer I’ve worked with, and all over the forums, people express their disdain for and frustration of managing overrides related to this monitor – and for good reason. It’s one of those monitors that touch every type of logical disk on every computer in the environment, and of course there are going to be different threshold requirements that require overrides – even the out-of-box flexibility of using both types of thresholds (mb and %) usually isn’t enough for us to “set it and forget it”.

This a great opportunity to reduce administrative overhead by enabling local administrators to change monitoring thresholds directly on the local machine, without having to login to the console and create overrides.

Because this is such a popular request, I’ve extended the Logical Disk Free Space monitor and added it to the Windows Monitoring (Extended) community pack.

Download the community pack from GitHub.

 

NOTE 1 – There are overrides defined in the pack that disable the vendor Logical Disk Free Space unit monitor. Once this pack is installed, that monitor will be replaced by this monitor. If you have overrides applied to the vendor monitors that you want to keep, those will need to be applied to this new unit monitor.

NOTE 2 – The unit monitor works out of the box exactly the same say as the original Logical Disk Free Space unit monitor. It will only behave differently if you implement the extended features of the unit monitor.

NOTE 3 – I chose to target Microsoft.Windows.LogicalDisk because the script data source, according to library documentation, should run fine against all versions of Windows. This reduces it from three monitors to just one.

 

Product knowledge has also been extended to include usage instructions:

image

 

An alert generated by this monitor will look like this:

image

 

A state change event (health explorer) for this monitor will look like this:

image

 

 

Smile

Monitor Percent Memory Used

I’ve seen this in the forums quite a bit, so I felt I should write a pack that monitor for Windows % memory used. I basically just took the script from the Windows packs, that claims (in the script comments) to work across all base Windows OS’s, and plugged it into a data source. Then I created a monitor type and a unit monitor.

I will post the xml here, but you can also download the management pack at the end of the post. I have only tested this on Windows 2008 and Windows 2012. As the base OS script says, it’s compatible with all versions. The default target of the unit monitor is Windows Server Operating System, so keep that in mind. The unit monitor is enabled by default. Because it target Windows Server Operating System, the Source of the alert will be just that; it will not be the computer name.

By default, it runs every 15 minutes and has a threshold of 90%. It will alert after 2 intervals over threshold. You can override interval, threshold, and match count. MatchCount is the number of intervals over threshold before generating an alert. You choose how you want to implement it 🙂

Here is the code:

<?xml version="1.0" encoding="utf-8"?>
<ManagementPack SchemaVersion="2.0" ContentReadable="true" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<Manifest>
<Identity>
<ID>Windows.Monitoring.Extended</ID>
<Version>1.0.0.19</Version>
</Identity>
<Name>Windows.Monitoring.Extended</Name>
<References>
<Reference Alias="Windows">
<ID>Microsoft.Windows.Library</ID>
<Version>7.5.8501.0</Version>
<PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
</Reference>
<Reference Alias="Health">
<ID>System.Health.Library</ID>
<Version>7.0.8432.0</Version>
<PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
</Reference>
<Reference Alias="System">
<ID>System.Library</ID>
<Version>7.5.8501.0</Version>
<PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
</Reference>
<Reference Alias="Perf">
<ID>System.Performance.Library</ID>
<Version>7.0.8432.0</Version>
<PublicKeyToken>31bf3856ad364e35</PublicKeyToken>
</Reference>
</References>
</Manifest>
<TypeDefinitions>
<ModuleTypes>
<DataSourceModuleType ID="Windows.Monitoring.Extended.DataSource.PercentMemoryUsed" Accessibility="Public" Batching="false">
<Configuration>
<xsd:element minOccurs="1" name="PhysicalMemory" type="xsd:double" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
<xsd:element minOccurs="1" name="IntervalSeconds" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
</Configuration>
<OverrideableParameters>
<OverrideableParameter ID="IntervalSeconds" Selector="$Config/IntervalSeconds$" ParameterType="int" />
</OverrideableParameters>
<ModuleImplementation Isolation="Any">
<Composite>
<MemberModules>
<DataSource ID="PerfDS" TypeID="Perf!System.Performance.DataProvider">
<CounterName>Available MBytes</CounterName>
<ObjectName>Memory</ObjectName>
<InstanceName />
<AllInstances>false</AllInstances>
<Frequency>$Config/IntervalSeconds$</Frequency>
</DataSource>
<ProbeAction ID="ScriptDS" TypeID="Windows!Microsoft.Windows.ScriptPropertyBagProbe">
<ScriptName>Microsoft.Windows.Server.OperatingSystem.PercentMemoryUsed.vbs</ScriptName>
<Arguments>$Data/Value$ $Config/PhysicalMemory$</Arguments>
<ScriptBody>
'Copyright (c) Microsoft Corporation. All rights reserved.

'*************************************************************************
' $ScriptName: "Microsoft.Windows.Server.Common"$
'
' Purpose: To have one place for common stuff across various BaseOS VBScripts
'
' $File: Microsoft.Windows.Server.Common.vbs$
'*************************************************************************

Option Explicit

SetLocale("en-us")

' LogScripEvent Constants
Const lsEventError = 1
Const lsEventWarning = 2
Const lsEventInformation = 3

' WMI Constants
Const wbemCimtypeUseDefault = 0 'Use Default Type CIM type - Custom
Const wbemCimtypeSint16 = 2 'Signed 16-bit integer
Const wbemCimtypeSint32 = 3 'Signed 32-bit integer
Const wbemCimtypeReal32 = 4 '32-bit real number
Const wbemCimtypeReal64 = 5 '64-bit real number
Const wbemCimtypeString = 8 'String
Const wbemCimtypeBoolean = 11 'Boolean value
Const wbemCimtypeObject = 13 'CIM object
Const wbemCimtypeSint8 = 16 'Signed 8-bit integer
Const wbemCimtypeUint8 = 17 'Unsigned 8-bit integer
Const wbemCimtypeUint16 = 18 'Unsigned 16-bit integer
Const wbemCimtypeUint32 = 19 'Unsigned 32-bit integer
Const wbemCimtypeSint64 = 20 'Signed 64-bit integer
Const wbemCimtypeUint64 = 21 'Unsigned 64-bit integer
Const wbemCimtypeDatetime = 101 'Date/time value
Const wbemCimtypeReference = 102 'Reference to a CIM object
Const wbemCimtypeChar16 = 103 '16-bit character

Const ErrAction_None = 0
Const ErrAction_Trace = 1
Const ErrAction_ThrowError = 16
Const ErrAction_Abort = 32
Const ErrAction_ThrowErrorAndAbort = 48

Dim g_ErrorEventNumber, g_TraceEventNumber, g_DebugFlag
g_ErrorEventNumber = 4001
g_TraceEventNumber = 4002
g_DebugFlag = False

'---------------------------------------------------------------------------
' Returns WMI Instance requested. Tries to execute WMI query a N times.
'---------------------------------------------------------------------------
Function WMIGetInstanceExTryN(oWMI, ByVal sInstance, ByVal N)
Dim oInstance, nInstanceCount
Dim e, i
Set e = New Error

For i = 0 To i &lt; N
On Error Resume Next
Set oInstance = oWMI.InstancesOf(sInstance)
e.Save
On Error Goto 0
If IsEmpty(oInstance) Or e.Number &lt;&gt; 0 Then
If i = N - 1 Then
ThrowScriptError "The class name '" &amp; sInstance &amp; "' returned no instances. Please check to see if this is a valid WMI class name.", e
End If
Else
On Error Resume Next
nInstanceCount = oInstance.Count
e.Save
On Error Goto 0
If e.Number &lt;&gt; 0 Then
If i = N - 1 Then
ThrowScriptError "The class name '" &amp; sInstance &amp; "' did not return any valid instances. Please check to see if this is a valid WMI class name.", e
End If
Else
Exit For
End If
End If
WScript.Sleep(1000)
Next

Set WMIGetInstanceExTryN = oInstance
End Function

'---------------------------------------------------------------------------
' Returns WMI Instance requested.
'---------------------------------------------------------------------------
Function WMIGetInstanceEx(oWMI, ByVal sInstance)
Dim oInstance, nInstanceCount
Dim e
Set e = New Error

On Error Resume Next
Set oInstance = oWMI.InstancesOf(sInstance)
e.Save
On Error Goto 0
If IsEmpty(oInstance) Or e.Number &lt;&gt; 0 Then
ThrowScriptError "The class name '" &amp; sInstance &amp; "' returned no instances. Please check to see if this is a valid WMI class name.", e
End If

'Determine if we queried a valid WMI class - Count will return 0 or empty
On Error Resume Next
nInstanceCount = oInstance.Count
e.Save
On Error Goto 0
If e.Number &lt;&gt; 0 Then
ThrowScriptError "The class name '" &amp; sInstance &amp; "' did not return any valid instances. Please check to see if this is a valid WMI class name.", e
End If

Set WMIGetInstanceEx = oInstance
End Function

'---------------------------------------------------------------------------
' Connect to WMI.
'---------------------------------------------------------------------------
Function WMIConnect(ByVal sNamespace)
Dim oWMI
Dim e
Set e = New Error
On Error Resume Next
Set oWMI = GetObject(sNamespace)
e.Save
On Error Goto 0
If IsEmpty(oWMI) Then
ThrowScriptError "Unable to open WMI Namespace '" &amp; sNamespace &amp; "'. Check to see if the WMI service is enabled and running, and ensure this WMI namespace exists.", e
End If
Set WMIConnect = oWMI
End Function

'---------------------------------------------------------------------------
' Returns WMI Instance requested.
'---------------------------------------------------------------------------
Function WMIGetInstance(ByVal sNamespace, ByVal sInstance)
Dim oWMI, oInstance
Set oWMI = WMIConnect(sNamespace)
Set oInstance = WMIGetInstanceEx(oWMI, sInstance)
Set WMIGetInstance = oInstance
End Function

'---------------------------------------------------------------------------
' Returns WMI Instance requested.
'---------------------------------------------------------------------------
Function WMIGetInstanceNoAbort(ByVal sNamespace, ByVal sInstance)
Dim oWMI, oInstance, nInstanceCount

On Error Resume Next
Set oWMI = GetObject(sNamespace)
If Not IsEmpty(oWMI) Then
Set oInstance = oWMI.InstancesOf(sInstance)
If Not IsEmpty(oInstance) And Err.Number = 0 Then
'Determine if we queried a valid WMI class - Count will return 0 or empty
nInstanceCount = oInstance.Count
If Err.Number = 0 Then
Set WMIGetInstanceNoAbort = oInstance
On Error Goto 0
Exit Function
End If
End If
End If

On Error Goto 0
Set WMIGetInstanceNoAbort = Nothing
End Function

'---------------------------------------------------------------------------
' Executes the WMI query and returns the result set.
'---------------------------------------------------------------------------
Function WMIExecQuery(ByVal sNamespace, ByVal sQuery)
Dim oWMI, oQuery, nInstanceCount
Dim e
Set e = New Error
On Error Resume Next
Set oWMI = GetObject(sNamespace)
e.Save
On Error Goto 0
If IsEmpty(oWMI) Then
ThrowScriptError "Unable to open WMI Namespace '" &amp; sNamespace &amp; "'. Check to see if the WMI service is enabled and running, and ensure this WMI namespace exists.", e
End If

On Error Resume Next
Set oQuery = oWMI.ExecQuery(sQuery)
e.Save
On Error Goto 0
If IsEmpty(oQuery) Or e.Number &lt;&gt; 0 Then
ThrowScriptError "The Query '" &amp; sQuery &amp; "' returned an invalid result set. Please check to see if this is a valid WMI Query.", e
End If

'Determine if we queried a valid WMI class - Count will return 0 or empty
On Error Resume Next
nInstanceCount = oQuery.Count
e.Save
On Error Goto 0
If e.Number &lt;&gt; 0 Then
ThrowScriptError "The Query '" &amp; sQuery &amp; "' did not return any valid instances. Please check to see if this is a valid WMI Query.", e
End If

Set WMIExecQuery = oQuery
End Function

'---------------------------------------------------------------------------
' Executes the WMI query and returns the result set, no abort version.
'---------------------------------------------------------------------------
Function WMIExecQueryNoAbort(ByVal sNamespace, ByVal sQuery)
Dim oWMI, oQuery
Set oWMI = GetObject(sNamespace)
Set oQuery = oWMI.ExecQuery(sQuery)
Set WMIExecQueryNoAbort = oQuery
End Function

'---------------------------------------------------------------------------
' Retrieves WMI property.
'---------------------------------------------------------------------------
Function GetWMIProperty(oWmi, sPropName, nCIMType, ErrAction)
Dim sValue, oWmiProp, oError
Set oError = New Error

' Check that object is valid.
If Not IsValidObject(oWmi) Then
If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "Accessing property on invalid WMI object.", oError
If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()

GetWMIProperty = ""
Exit Function
End If

' Get properties...
On Error Resume Next
Set oWmiProp = oWmi.Properties_.Item(sPropName)
oError.Save
If oError.Number &lt;&gt; 0 Then
If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "An error occurred while accessing WMI property: '" &amp; sPropName &amp; "'.", oError
If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()
End If
On Error Goto 0

If IsValidObject(oWmiProp) Then
sValue = oWmiProp.Value

If IsNull(sValue) Then ' If value is null, return blank to avoid any issues
GetWMIProperty = ""
Else
Select Case (oWmiProp.CIMType)
Case wbemCimtypeString, wbemCimtypeSint16, wbemCimtypeSint32, wbemCimtypeReal32, wbemCimtypeReal64, wbemCimtypeSint8, wbemCimtypeUint8, wbemCimtypeUint16, wbemCimtypeUint32, wbemCimtypeSint64, wbemCimtypeUint64:
If Not oWmiProp.IsArray Then
GetWMIProperty = Trim(CStr(sValue))
Else
GetWMIProperty = Join(sValue, ", ")
End If
Case wbemCimtypeBoolean:
If sValue = 1 Or UCase(sValue) = "TRUE" Then
GetWMIProperty = "True"
Else
GetWMIProperty = "False"
End If
Case wbemCimtypeDatetime:
Dim sTmpStrDate

' First attempt to convert the whole wmi date string
sTmpStrDate = Mid(sValue, 5, 2) &amp; "/" &amp; _
Mid(sValue, 7, 2) &amp; "/" &amp; _
Left(sValue, 4) &amp; " " &amp; _
Mid (sValue, 9, 2) &amp; ":" &amp; _
Mid(sValue, 11, 2) &amp; ":" &amp; _
Mid(sValue, 13, 2)
If IsDate(sTmpStrDate) Then
GetWMIProperty = CDate(sTmpStrDate)
Else
' Second, attempt just to convert the YYYYMMDD
sTmpStrDate = Mid(sValue, 5, 2) &amp; "/" &amp; _
Mid(sValue, 7, 2) &amp; "/" &amp; _
Left(sValue, 4)
If IsDate(sTmpStrDate) Then
GetWMIProperty = CDate(sTmpStrDate)
Else
' Nothing works - return passed in string
GetWMIProperty = sValue
End If
End If
Case Else:
GetWMIProperty = ""
End Select
End If
Else
If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "An error occurred while accessing WMI property: '" &amp; sPropName &amp; "'.", oError
If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()

GetWMIProperty = ""
End If

If (ErrAction And ErrAction_Trace) = ErrAction_Trace Then _
WScript.Echo " + " &amp; sPropName &amp; " :: '" &amp; GetWMIProperty &amp; "'"
End Function

'---------------------------------------------------------------------------
' Class for error handling.
'---------------------------------------------------------------------------
Class Error
Private m_lNumber
Private m_sSource
Private m_sDescription
Private m_sHelpContext
Private m_sHelpFile
Public Sub Save()
m_lNumber = Err.number
m_sSource = Err.Source
m_sDescription = Err.Description
m_sHelpContext = Err.HelpContext
m_sHelpFile = Err.helpfile
End Sub
Public Sub Raise()
Err.Raise m_lNumber, m_sSource, m_sDescription, m_sHelpFile, m_sHelpContext
End Sub
Public Sub Clear()
m_lNumber = 0
m_sSource = ""
m_sDescription = ""
m_sHelpContext = ""
m_sHelpFile = ""
End Sub
Public Default Property Get Number()
Number = m_lNumber
End Property
Public Property Get Source()
Source = m_sSource
End Property
Public Property Get Description()
Description = m_sDescription
End Property
Public Property Get HelpContext()
HelpContext = m_sHelpContext
End Property
Public Property Get HelpFile()
HelpFile = m_sHelpFile
End Property
End Class

'---------------------------------------------------------------------------
' Creates an event and sends it back to the mom server.
'---------------------------------------------------------------------------
Function ThrowScriptErrorNoAbort(ByVal sMessage, ByVal oErr)
' Retrieve the name of this (running) script
Dim FSO, ScriptFileName
Set FSO = CreateObject("Scripting.FileSystemObject")
ScriptFileName = FSO.GetFile(WScript.ScriptFullName).Name
Set FSO = Nothing

If Not IsNull(oErr) Then _
sMessage = sMessage &amp; ". " &amp; oErr.Description

On Error Resume Next
Dim oAPITemp
Set oAPITemp = CreateObject("MOM.ScriptAPI")
oAPITemp.LogScriptEvent ScriptFileName, g_ErrorEventNumber, lsEventError, sMessage
On Error Goto 0

WScript.Echo sMessage
End Function

'---------------------------------------------------------------------------
' Creates an event and sends it back to the mom server.
'---------------------------------------------------------------------------
Function ThrowScriptError(Byval sMessage, ByVal oErr)
On Error Resume Next
ThrowScriptErrorNoAbort sMessage, oErr
Quit()
End Function

'---------------------------------------------------------------------------
' Creates automation objects and returns it.
'---------------------------------------------------------------------------
Function MomCreateObject(ByVal sProgramId)
Dim oError
Set oError = New Error

On Error Resume Next
Set MomCreateObject = CreateObject(sProgramId)
oError.Save
On Error Goto 0

If oError.Number &lt;&gt; 0 Then
ThrowScriptError "Unable to create automation object '" &amp; sProgramId &amp; "'", oError
End If
End Function

'---------------------------------------------------------------------------
' Quits the script.
'---------------------------------------------------------------------------
Function Quit()
WScript.Quit()
End Function

'---------------------------------------------------------------------------
' Checks whether oObject is valid.
'---------------------------------------------------------------------------
Function IsValidObject(ByVal oObject)
IsValidObject = False
If IsObject(oObject) Then
If Not oObject Is Nothing Then
IsValidObject = True
End If
End If
End Function

'---------------------------------------------------------------------------
' Outputs arguments for debugging purposes
'---------------------------------------------------------------------------
Function TraceLogArguments
Dim oArgs
Set oArgs = WScript.Arguments
Dim i, sArgs
For i = 0 To oArgs.Count - 1
sArgs = sArgs &amp; " {" &amp; oArgs(i) &amp; "}"
Next
TraceLogMessage "Arguments:" &amp; sArgs
End Function

'---------------------------------------------------------------------------
' Verifies that number of arguments is correct
'---------------------------------------------------------------------------
Function VerifyNumberOfArguments(ByVal NumberOfArguments)
Dim oArgs
Set oArgs = WScript.Arguments
If oArgs.Count &lt;&gt; NumberOfArguments Then
Dim i, sArgs
For i = 0 To oArgs.Count - 1
sArgs = sArgs &amp; " {" &amp; oArgs(i) &amp; "}"
Next
ThrowScriptError "Invalid number of arguments (" &amp; oArgs.Count &amp; " instead of " &amp; NumberOfArguments &amp; "). Arguments:" &amp; sArgs, Null
End If
End Function

'---------------------------------------------------------------------------
' Outputs to file and echo for debugging purposes
'---------------------------------------------------------------------------
Function TraceLogMessage(ByVal sMessage)
WScript.Echo sMessage

If g_DebugFlag = True Then
' Retrieve the name of this (running) script
Dim FSO, ScriptFileName
Set FSO = CreateObject("Scripting.FileSystemObject")
ScriptFileName = FSO.GetFile(WScript.ScriptFullName).Name
Set FSO = Nothing

On Error Resume Next
Dim oAPITemp
Set oAPITemp = MOMCreateObject("MOM.ScriptAPI")
oAPITemp.LogScriptEvent ScriptFileName, g_TraceEventNumber, lsEventInformation, sMessage
On Error Goto 0
End If
End Function

'---------------------------------------------------------------------------
' Verifies the expression. If equals to False then generates an error and quits the script
' Usage:
' Verify Not WMISet Is Nothing, "WMISet is invalid!"
' Verify WMISet.Count = 1, "Invalid quantity of services with name 'Server' (qty = " &amp; WMISet.Count &amp; ")."
'---------------------------------------------------------------------------
Function Verify(ByVal bBool, ByVal sMessage)
If bBool = False Then
ThrowScriptError sMessage, Null
End If
End Function


Function GetRegistryKeyValue(ByVal keyPath, ByVal key)
Dim oReg, strKeyValue

Set oReg = MOMCreateObject("WScript.Shell")
On Error Resume Next

strKeyValue = oReg.RegRead(keyPath &amp; key)
If Err.Number &lt;&gt; 0 Then
ThrowScriptError "An error occurred while reading the registry: '" &amp; keyPath &amp; key &amp; "'", Err.Description
strKeyValue = ""
End If

' resume error
On Error Goto 0

GetRegistryKeyValue = strKeyValue
End Function
'Copyright (c) Microsoft Corporation. All rights reserved.

'*************************************************************************
' $ScriptName: "Microsoft.Windows.Server.OperatingSystem.PercentMemoryUsed"$
'
'
' $File: Microsoft.Windows.Server.OperatingSystem.PercentMemoryUsed.vbs$
'*************************************************************************

' Parameters that should be passed to this script
' 0 Available Physical memory MBytes.
' 1 Total amount of Physical Memory in KBytes.

Const sCounterName = "PercentMemoryUsed"
Const sObjectName = "Memory"

Call Main()

Sub Main

VerifyNumberOfArguments(2)

Dim oArgs, sErrorDescription
Set oArgs = WScript.Arguments

Dim nAvailableMBytes, nPhysicalMemoryKBytes, nPhysicalMemoryMBytes, oAPI, nResult, oBag

nAvailableMBytes = oArgs(0)
nPhysicalMemoryKBytes = oArgs(1)
nResult = 0
sErrorDescription = "Invalid arguments are detected: " &amp; nAvailableMBytes &amp; " " &amp; nPhysicalMemoryKBytes

If Not (IsNumeric(nAvailableMBytes) And IsNumeric(nPhysicalMemoryKBytes)) Then
ThrowScriptError sErrorDescription, Null
End If

nPhysicalMemoryMBytes = CDbl(nPhysicalMemoryKBytes/1024)

If (CDbl(nAvailableMBytes) &gt; 0) Then

If Not (CDbl(nAvailableMBytes) &lt; CDbl(nPhysicalMemoryMBytes)) Then
ThrowScriptError sErrorDescription, Null
End If

Set oAPI = MOMCreateObject("MOM.ScriptAPI")
Set oBag = oAPI.CreateTypedPropertyBag(2)

nResult = CDbl(100 - (nAvailableMBytes/(nPhysicalMemoryMBytes)*100))

With oBag
.AddValue "PerfCounter", sCounterName
.AddValue "PerfValue", nResult
End With

oAPI.AddItem oBag

oAPI.ReturnItems

End If

End Sub
</ScriptBody>
<TimeoutSeconds>300</TimeoutSeconds>
</ProbeAction>
<ConditionDetection ID="PerfMapper" TypeID="Perf!System.Performance.DataGenericMapper">
<ObjectName>Memory</ObjectName>
<CounterName>$Data/Property[@Name='PerfCounter']$</CounterName>
<InstanceName />
<Value>$Data/Property[@Name='PerfValue']$</Value>
</ConditionDetection>
<ConditionDetection ID="IsNullCD" TypeID="System!System.ExpressionFilter">
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">/DataItem/IsNull</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">false</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</ConditionDetection>
</MemberModules>
<Composition>
<Node ID="PerfMapper">
<Node ID="ScriptDS">
<Node ID="IsNullCD">
<Node ID="PerfDS" />
</Node>
</Node>
</Node>
</Composition>
</Composite>
</ModuleImplementation>
<OutputType>Perf!System.Performance.Data</OutputType>
</DataSourceModuleType>
</ModuleTypes>
<MonitorTypes>
<UnitMonitorType ID="Windows.Monitoring.Extended.MonitorType.PercentMemoryUsed" Accessibility="Public">
<MonitorTypeStates>
<MonitorTypeState ID="MTS_Over" />
<MonitorTypeState ID="MTS_Under" />
</MonitorTypeStates>
<Configuration>
<xsd:element minOccurs="1" name="PhysicalMemory" type="xsd:double" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
<xsd:element minOccurs="1" name="IntervalSeconds" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
<xsd:element minOccurs="1" name="Threshold" type="xsd:double" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
<xsd:element minOccurs="1" name="MatchCount" type="xsd:integer" xmlns:xsd="http://www.w3.org/2001/XMLSchema" />
</Configuration>
<OverrideableParameters>
<OverrideableParameter ID="IntervalSeconds" Selector="$Config/IntervalSeconds$" ParameterType="int" />
<OverrideableParameter ID="Threshold" Selector="$Config/Threshold$" ParameterType="double" />
<OverrideableParameter ID="MatchCount" Selector="$Config/MatchCount$" ParameterType="int" />
</OverrideableParameters>
<MonitorImplementation>
<MemberModules>
<DataSource ID="Script" TypeID="Windows.Monitoring.Extended.DataSource.PercentMemoryUsed">
<PhysicalMemory>$Config/PhysicalMemory$</PhysicalMemory>
<IntervalSeconds>$Config/IntervalSeconds$</IntervalSeconds>
</DataSource>
<ConditionDetection ID="CD_Under" TypeID="System!System.ExpressionFilter">
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Double">Value</XPathQuery>
</ValueExpression>
<Operator>Less</Operator>
<ValueExpression>
<Value Type="Double">$Config/Threshold$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</ConditionDetection>
<ConditionDetection ID="CD_Over" TypeID="System!System.ExpressionFilter">
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Double">Value</XPathQuery>
</ValueExpression>
<Operator>GreaterEqual</Operator>
<ValueExpression>
<Value Type="Double">$Config/Threshold$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<SuppressionSettings>
<MatchCount>$Config/MatchCount$</MatchCount>
</SuppressionSettings>
</ConditionDetection>
</MemberModules>
<RegularDetections>
<RegularDetection MonitorTypeStateID="MTS_Under">
<Node ID="CD_Under">
<Node ID="Script" />
</Node>
</RegularDetection>
<RegularDetection MonitorTypeStateID="MTS_Over">
<Node ID="CD_Over">
<Node ID="Script" />
</Node>
</RegularDetection>
</RegularDetections>
</MonitorImplementation>
</UnitMonitorType>
</MonitorTypes>
</TypeDefinitions>
<Monitoring>
<Monitors>
<UnitMonitor ID="Windows.Monitoring.Extended.Monitor.PercentMemoryUsed" Accessibility="Public" Enabled="true" ParentMonitorID="Health!System.Health.PerformanceState" Priority="Normal" Target="Windows!Microsoft.Windows.Server.OperatingSystem" TypeID="Windows.Monitoring.Extended.MonitorType.PercentMemoryUsed">
<Category>PerformanceHealth</Category>
<AlertSettings AlertMessage="Windows.Monitoring.Extended.AlertMessage.PercentMemoryUsed">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Value$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="OpState_Healthy" HealthState="Success" MonitorTypeStateID="MTS_Under" />
<OperationalState ID="OpState_Unhealty" HealthState="Error" MonitorTypeStateID="MTS_Over" />
</OperationalStates>
<Configuration>
<PhysicalMemory>$Target/Property[Type="Windows!Microsoft.Windows.OperatingSystem"]/PhysicalMemory$</PhysicalMemory>
<IntervalSeconds>900</IntervalSeconds>
<Threshold>90</Threshold>
<MatchCount>2</MatchCount>
</Configuration>
</UnitMonitor>
</Monitors>
</Monitoring>
<Presentation>
<StringResources>
<StringResource ID="Windows.Monitoring.Extended.AlertMessage.PercentMemoryUsed" />
</StringResources>
</Presentation>
<LanguagePacks>
<LanguagePack ID="ENU" IsDefault="true">
<DisplayStrings>
<DisplayString ElementID="Windows.Monitoring.Extended.Monitor.PercentMemoryUsed">
<Name>Windows Percent Memory Used Monitor</Name>
</DisplayString>
<DisplayString ElementID="Windows.Monitoring.Extended.AlertMessage.PercentMemoryUsed">
<Name>Windows Memory Over Threshold</Name>
<Description>Windows memory is currently at 0: {0}%</Description>
</DisplayString>
</DisplayStrings>
<KnowledgeArticles></KnowledgeArticles>
</LanguagePack>
</LanguagePacks>
</ManagementPack>

Here is the link to the full management pack xml download.

 

If you have a request for a new rule or unit monitor, ask in the comments section and I’ll do what I can to expand on this pack.

_